       XXVIII Annual Congress of the Iranian Society of Ophthalmology        بـیــست و هشتمین کنــگــره سـالیـانه انـجـمـن چـشـم پـزشـکی ایـــران
مقاله Abstract


Title: Agreement between Pentacam and handheld Auto-Refractor/ Keratometers for keratometry measurement
Author(s): Hassan Hashemi, Frida Jabbari-Azad, Nooshin Dadbin, Mojgan Pakbin, AbbasAli Yekta, Mehdi Khabazkhoob
Presentation Type: Poster
Subject: Cornea and Anterior Segment
Others:
Presenting Author:
Name: Frida Jabbari azad
Affiliation :(optional) Noor Research Center for Ophthalmic Epidemiology, Noor Eye Hospital, Tehran, Iran
E mail: frida.jbr@gmail.com
Phone: 22611327
Mobile: 09129247463
Purpose:

This study purposed to evaluate the level of agreement in keratometry measurements with Pentacam and handheld Auto-Refractor/ Keratometers.

Methods:

This analytical cross-sectional study was conducted on the right eyes of 579 people. Keratometry measurements were conducted with Pentacam and the handheld auto-refracto-keratometer. The SPSS Software version 22 was used to estimate descriptive statistics, paired t-test, the Pearson correlation coefficient, and 95% limits of agreement (LoA).

Results:

In the total sample, the inter-device difference in mean flat and steep keratometry values were -0.266 diopter (D) (P-value <0.001) and 0.052 D (P-value = 0.093), respectively. There was a significant difference in mean flat keratometry between the two devices in all groups of refractive error (paired difference <0.5 D and P-value <0.001). The difference in mean steep keratometry was significant only in myopic subjects (P-value = 0.046). The 95% LoA for the two devices was less than 1.0 D only in the under 6-year age group.

Conclusion:

The difference between two devices in measurements of steep keratometry was small and clinically acceptable in the total sample as well as in groups by refractive error. However, given the wide 95% LoA, the two devices should not be used interchangeably in the study of refractive error and age groups, except under 6-year-olds in which the 95% LoA is less than 1.0 D, and thus, the handheld auto-refracto-keratometer can serve as a substitute for Pentacam in situations such as screening.

Attachment: 84AGREEMENT BETWEEN PENTACAM AND HANDHELD AUTO-.pptx





Skip Navigation Links
        صفحه اصلی
        ساختار کنگره
        تاریخ های مهم
        مکان برگزاری
        ثبت نام
        ثبت نام شدگان
        اطلاعات هتل - رزرو
        مقالات
        برنامه کنگره
        جشنواره فیلم و عکس
        نمایشگاه
        تماس با ما
        صفحه شخصی
        جستجوی سخنران
        آرشیو کنگره سالهای گذشته
        شب کنگره چشم پزشکی
 
ورود شرکت کنندگان
نام کاربری :
کلمه عبور :
  کلمه عبور خود را فراموش کرده ام.
Total Visits
Find us on Social Media
Congress Count Down
Today Label
Last Month Label
Total Visitors Label