Title: Clinical outcomes of new toric trifocal diffractive intraocular lens in patients with cataract and stable keratoconus: 30 months follow-up
Author(s): Farideh Doroodgar1,Mohammad Ghoreishi, Azad Sanginabadi,Alireza Baradaran-Rafie,
Presentation Type: Poster
Subject: Cornea and Anterior Segment
Others:
Presenting Author:
Name: Farideh Doroodgar
Affiliation :(optional) Negah eye hospital
E mail: farinaz_144@yahoo.com
Phone: 09125259912
Mobile: 09125259912
Purpose:

To evaluate the clinical results of toric trifocal diffractive Intraocular lens in eyes with cataract and mild keratoconus.

Methods:

Five keratoconus patients (10 eyes) that had bilateral AT LISA 939 implantation of were selected and had followed in three-time horizons of 1 and 3months, and 2 years. Patients were 46 to 65 years old age, corneal astigmatism of (2.00 D at 6.75) and cataract that all of them needed cataract surgery. The distance, intermediate and near visual acuities, defocus curve, ocular aberrations, contrast sensitivity, were measured as effectiveness criteria.

Results:

Average of binocular uncorrected distance visual acuity (UDVA) improved from 0.72 logMAR ± 0.11 (SD) to 0.04 ± 0.04 (p ˂0.05) log MAR, average of uncorrected binocular intermediate visual acuity (UIVA) (80 cm) improved from 0.52 ± 0.07 log MAR to 0.14 ± 0.04 (p˂0.05) log MAR and average of binocular uncorrected near visual acuity (UNVA) improved from 0.48 ± 0.09 log MAR to 0.02 ± 0.07 (p ˂0.05) LogMAR at 30 months, respectively. Contrast sensitivity testing showed acceptable results ,the binocular defocus curve corroborate were in appropriate good visual acuity even at the intermediate distances, by a gentle slope less than Log MAR 0.2 at −1.5 D, with regard to the best distance visual acuity at the 0 D defocus

Conclusion:

Trifocal AT LISA 939MP IOLs provided appropriate distances, near and intermediate of the visual results. Prediction of the refractive results and optical performances were good.

Attachment: 57Dr.Doroodgar_Clinical.pptx





Skip Navigation Links
        صفحه اصلی
        ساختار کنگره
        تاریخ های مهم
        مکان برگزاری
        ثبت نام
        ثبت نام شدگان
        اطلاعات هتل - رزرو
        مقالات
        برنامه کنگره
        جشنواره فیلم و عکس
        نمایشگاه
        تماس با ما
        صفحه شخصی
        جستجوی سخنران
        آرشیو کنگره سالهای گذشته
        شب کنگره چشم پزشکی
 
ورود شرکت کنندگان
نام کاربری :
کلمه عبور :
  کلمه عبور خود را فراموش کرده ام.
Total Visits
Find us on Social Media
Congress Count Down
Today Label
Last Month Label
Total Visitors Label