image 2 image 4
Skip Navigation Links
 Home 
 Congress Structure 
 Important Dates 
 Venue 
 Registration 
 Pre Registered 
 Abstracts 
 Scientific Program 
 Photo and Film Festival 
 Exhibition 
 Contact Us 
 Personal page 
       XXVIII Annual Congress of the Iranian Society of Ophthalmology        بـیــست و هشتمین کنــگــره سـالیـانه انـجـمـن چـشـم پـزشـکی ایـــران
مقاله Abstract


Title: Comparison of graft thickness measured by eye bank with graft thickness measured after DSAEK
Author(s): Sepehr Feizi, Siamak Delfazayebaher, Ali Masoudi
Presentation Type: Oral
Subject: Cornea and Anterior Segment
Others:
Presenting Author:
Name: Sepehr Feizi
Affiliation :(optional) Ophthalmic Research Center, Shahid Beheshti University of Medical Sciences
E mail: sepehrfeizi@yahoo.com
Phone: 22773857
Mobile: 09122837429
Purpose:

To compare donor lenticule thickness reported by the eye bank with lenticule thickness measured at 6 months after Descemet stripping automated endothelial keratoplasty (DSAEK).

Methods:

This prospective, interventional case series enrolled 30 eyes from 30 patients who underwent DSAEK using precut eye bank tissue. Preoperative thickness measurements of the donor lenticules were taken centrally and at pericentral and peripheral graft areas using an anterior segment optical coherence tomography system. The same measurements were repeated 6 months postoperatively. The preoperative and postoperative values were compared, and the relationships between these measurements were investigated using Pearson correlation coefficients.

Results:

The mean donor age was 47.7±10.7 years old. The mean preoperative endothelial cell density was 3016.8±361.4 cells/mm2, which decreased to 1644.9±482.0 cells/mm2 postoperatively (P<0.001). The graft thickness of the precut tissue, as reported by the eye bank, was 136.8±24.9 µm at the center, 149.4±27.3 µm at the pericentral area, and 198.4±32.8 µm at the periphery. The corresponding postoperative values were 119.2±29.8 µm (P=0.004), 124.5±34.6 µm (P=0.002), and 156.3±45.4 µm (P<0.001), respectively. The graft thickness measured by the eye bank was significantly associated with that measured in vivo at 6 months at the central (r=0.63, P=0.001) and pericentral (r=0.50, P=0.009) graft area. However, the correlation between preoperative and postoperative peripheral graft thickness was insignificant (P=0.14).

Conclusion:

Compared to preoperative values, central, pericentral and peripheral graft thicknesses were reduced by 10.4%, 14.2%, and 18.4%, respectively, 6 months after DSAEK. Postoperative graft thinning was greater at the periphery compared with the central and pericentral area.

Attachment:





Skip Navigation Links
        صفحه اصلی
        ساختار کنگره
        تاریخ های مهم
        مکان برگزاری
        ثبت نام
        ثبت نام شدگان
        اطلاعات هتل - رزرو
        مقالات
        برنامه کنگره
        جشنواره فیلم و عکس
        نمایشگاه
        تماس با ما
        صفحه شخصی
        جستجوی سخنران
        آرشیو کنگره سالهای گذشته
        شب کنگره چشم پزشکی
 
ورود شرکت کنندگان
نام کاربری :
کلمه عبور :
  کلمه عبور خود را فراموش کرده ام.
Total Visits
Find us on Social Media
Congress Count Down
Today Label
Last Month Label
Total Visitors Label